HOWLINE


⠀The charity that supports werewolves
Support Hotline: 0142 067 0691 info@howline.org.uk

Building safe changing areas

The right to a secure area to change for werewolves has been enshrined in law since 1934, with the Provision of Lycanthropic Changing Areas Act. Despite being relatively revolutionary at the time, the ideas laid out in the Act have long since started to show their age. Not only that, but the actual changing areas aren't held to any kind of standardised guidelines. Howline aims to change that. Our latest campaign, Campaigning for Change, is aimed to create a set of standards for all changing areas across the UK. We've already created our own guidelines with which we hope to base the new standards on. Many of our partners already utilise these guidelines to create the best enviroment possible for all werewolves.

Howline’s Guidelines

Howline has worked with werewolf experts, our own members, and members of the public to create a set of guidelines for the werewolf changing area.
Our current guidelines for a safe changing area are listed below:

    SIZE

  • At minimum, a changing room should be no less then 3 metres by 3 metres, with a 3 metre ceiling. This is to allow sufficient space to transform, stand, pace, and exhibit a full range of natural movement for even the largest wolves. Each room should be used for one person at a time- children may enter with their guardians if necessary. People should NEVER be made to share a room when changing.
  • MATERIALS

  • Rooms should be made of concrete, steel, or masonry. Metal mesh is NOT recommended – neighbouring persons should not be able to see each other for privacy. If metal mesh is used, it should be covered by some kind of screening material that is not easily torn and does not pose a health hazard if ingested. Rooms should have smooth walls with no extruding objects or shapes. A double barrier system is recommended in case of failure. Ceilings should be as reinforced as walls are. Windows can be implemented if the opening is no wider then 30cm by 15cm, though glass used should be reinforced and ideally behind metal bars or metal mesh.
  • FLOORING

  • Flooring should be concrete and non-slip, to prevent injuries. Carpets and wooden flooring is not recommended as these can be torn up and potentially ingested or cause injury. A drain should be implemented into the floor to allow ease of cleaning of rooms. Floors should be on a slight incline to ensure sufficient drainage.
  • LIGHTING

  • Lights should be flush within the ceiling itself, with no protruding lip or edges that could be caught. Lights should sufficiently illuminate the room. Lighting should be controlled via an external light switch within the airlock system. Lights should not be glass and must be made of shatter-proof materials.
  • HEATING

  • Rooms should have heating and maintain a steady temperature of at least 15°C or higher. There should be no radiators in rooms themselves – if radiators are present, they should be cast iron, and firmly secured to the wall and floor to prevent any risk of falling or being pulled out.
  • VENTILATION

  • All rooms should be sufficiently ventilated but not draughty. We don’t recommend rooms venting into neighbouring rooms as this can cause distress to wolves when they smell strangers.
  • DOOR SYSTEM

  • Doors should be built of reinforced materials and have secure locking systems, such as spring-loaded latches, sliding dead bolts, or cam locks. There should be a security airlock double-door system in place, with controls for the room (lighting, locks, heating if applicable) located within the airlock to prevent external tampering while the user is in the room. A safe and a shelf or unit should be present in the airlock as well, for users to place their clothing and other items and valuables. A system should be in place to indicate when a room is in use.
  • LOCATION

  • Changing areas should be built away from heavily populated areas, but close enough to ensure accessibility for people who don’t have access to personal transport or those who have disabilities. Public transport services should be provided for access to the changing building, for example a dedicated bus service. There should be at least four rooms available on the ground floor of a building for access for disabled users.
  • HYGIENE

  • Changing rooms should be checked after every use and cleaned once weekly, if not more. Amenities should be functional and checked monthly, and replaced if necessary. Any broken items should be removed immediately. Rooms with true structural damage should be closed to public use and repaired as quickly as possible. Aesthetic damage (claw marks, staining) is acceptable if it does not pose any risk. The entire building should be secured against pests, however, poisons must NOT be utilised as pest control due to risk of ingestion by wolves.
  • FIRE SAFETY

  • The entire building must comply to current fire codes. Door locks should unlock automatically in case of fire. Fire alarms must be present throughout the building and all fire exits must be clearly marked.
  • ENRICHMENT

  • Howline recommends providing some form of enrichment within the changing rooms themselves. Large logs are a good form of enrichment for wolves, allowing scratching and tearing behaviours. We do not recommend providing meat or carcasses for public use, and users should be discouraged from bringing any kind of large meat or carcasses with them due to hygiene concerns. Users should be allowed to bring their own enrichment if it is not biological, however please encourage them to take it home once they are done using the area.